FREE SHIPPING $500.00 OR MORE CODE FSHIP12.
NO CHEMICALS/GLASSWARE 1.800.967.5316
|
HANNA EC Meter with USP |
| | Quantity in Basket:
none Code: 98188
Price:$789.00
|
| EC Meter with USP
This meter can perform all 3 stages of USP <645> water quality testing requirements.
Both linear and natural water temperature compensation is available and the reference temperature is user adjustable.
Meter displays progress towards meeting stage 2 stability requirements.
HI 98188 conductivity meter has an extended range from 0.001 µS/cm to 400 mS/cm, as well as resistivity and 3 salinity scales. This meter also automatically recognizes the probe type (2 or 4-ring and nominal cell constant). Both linear and natural water temperature compensation is available and the reference temperature is user adjustable. Ten sets of measurement parameters (such as reference temperature, temperature compensation mode, TDS factor, calibration etc.) can be stored as a user profile for later use. Other features include USP <645> stages 1, 2 and 3 mode, up to 5 calibration points, log-ondemand and interval logging.
HI 98188 is supplied with HI 76310 4-ring conductivity probe with built-in temperature sensor, calibration solution; (4) 1.2V AA, 1300 mAh rechargeable batteries; HI 710042-01 inductive battery charger with power adapter; rugged carrying case and instructions.
Available Accessories:
Coming Soon |
Specifications:
Range (EC) 0 to 400mS/cm (actual conductivity 1000 mS/cm) 0.001 to 9.999 µS/cm; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (autoranging)
Resolution (EC) 0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy (EC) ±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater)
Range (Resistivity) 1 to 999.9 Ohmcm; 1.000 to 9.999 kOhmcm; 10.00 to 99.99 kOhmcm; 100.0 to 999.9 kOhmcm; 1.0 to 100.0 MOhmcm (autoranging)
Resolution (Resistivity) 0.1 Ohmcm; 0.001 kOhmcm; 0.01 kOhmcm; 0.1 kOhmcm; 0.1 MOhmcm
Accuracy (Resistivity) ±2% of reading (±1 Ohmcm or 1 digit, whichever is greater)
Range (TDS) 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 g/L; 10.00 to 99.99 g/L; 100.0 to 400.0 g/L (autoranging)
Resolution (TDS) 0.01 ppm; 0.1 ppm; 0.001 g/L; 0.01 g/L; 0.1 g/L
Accuracy (TDS) ±1% of reading (±0.05 ppm or 1 digit, whichever is greater)
Range (NaCl) %: 0.0 to 400.0%; seawater scale: 0.00 to 80.00 (PSU); Practical salinity: 0.01 to 42.00
Resolution (NaCl) 0.1%; 0.01
Accuracy (NaCl) ±1% of reading
Range (Temp) -20.0 to 120.0°C
Resolution (Temp) 0.1°C
Accuracy (Temp) ±0.2°C (excluding probe error)
Calibration (EC) Automatic up to 5 points with 7 memorized standards (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
Calibration (NaCl) 1 point only in % range (with HI 7037 buffer); Use conductivity calibration for all other ranges
Calibration (Temp) 1 or 2 points
Temperature Compensation -20.0 to 120.0°C
Reference Temperature 15°C, 20°C and 25°C
TDS Factor 0.40 to 1.00
Probe HI 76310 4-ring EC probe with built-in temperature sensor
Logging (Log-on-demand) 400 samples
Logging (Interval) 5 seconds to 1 minute
PC Connectivity Opto-isolated USB (with HI 92000 software)
Battery Type/Life (4) 1.2V AA rechargeable batteries/approx. 100 hrs continuous use (without backlight)
Recharger Inductive recharger (included)
Auto-off User Selectable: 5, 10, 30, 60 min or can be disabled
Environment IP67
Dimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2)
Weight 525 g
|
| |