Runtime error in lib/db.mvc @ [00000006:00000372]: Line 157: MvADD: Error writing to 'Merchant2/00000001/basklist.dbf': Tris buffer meter HI223 with HI1043P pH electrode: BC Scientific
 


 Store FrontAccountSearchProduct ListBasket Contents Checkout 
Sign In

BEAKERS
CYLINDERS
FUNNELS
CHEMICALS
GLOVES
CLEANING CHEMICALS
BOILING/FLORENCE FLASKS
ERLENMEYER FLASKS
FILTERING FLASKS
VOLUMETRIC FLASKS
FLASKS
PH/CHLORINE TEST STRIPS
A** CHEMICALS
B** CHEMICALS
C** CHEMICALS
D** CHEMICALS
E** CHEMICALS
F** CHEMICALS
G** CHEMICALS
H** CHEMICALS
I** CHEMICALS
J** CHEMICALS
K** CHEMICALS
L** CHEMICALS
M** CHEMICALS
N** CHEMICALS
O** CHEMICALS
P** CHEMICALS
Q** CHEMICALS
R** CHEMICALS
S** CHEMICALS
T** CHEMICALS
U** CHEMICALS
V** CHEMICALS
W** CHEMICALS
X** CHEMICALS
Y** CHEMICALS
Z** CHEMICALS

FREE SHIPPING $500.00 OR MORE CODE FSHIP12.
NO CHEMICALS/GLASSWARE
1.800.967.5316

Tris buffer meter HI223 with HI1043P pH electrode

 
Tris buffer meter HI223 with HI1043P pH electrodeQuantity in Basket: none
Code: HI223TRIS
Price:$647.00

 
 

Promotion Code: 
 
Quantity:
 
Tris buffer meter HI223 with HI1043P pH electrode back to products HI 223 pH Meters with Calibration Check Description A pH electrode that is properly manufactured and kept clean will retain its measuring integrity for quite a long time. The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note because, during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset of approximately ±60 mV. The deviation from 0 mV is not unusual, in fact it represents the true characteristics of the pH electrode. The deviation from 0 mV becomes a problem if it is the result of calibrating a dirty electrode. HANNA®' HI 221 & HI 223 compare the characteristics of the pH electrode from one calibration to the next. In case of large variances in the electrode condition that can only be the result of a soiled sensor, these meters alert the user that the electrode needs to be properly cleaned prior to calibration and measuring. Specifications Range pH -2.00 to 16.00 pH; -2.000 to 16.000 pH Range mV ±699.9 mV; ±2000 mV Range Temperature -20.0 to 120.0°C Resolution pH 0.01 pH; 0.001 pH Resolution mV 0.1 (±999.9 mV); 1 (±2000 mV) Resolution Temperature 0.1°C Accuracy pH ±0.01 pH; ±0.002 pH Accuracy mV ±0.2 (±699.9 mV); ±0.5 (±999.9 mV); ±1 (±2000 mV) Accuracy Temperature ±0.4°C Calibration Check status of electrode condition and response time, status of the buffer solution during calibration pH Calibration automatic, up to 5 points with 7 memorized values (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) Temperature Compensation manual or automatic, -20.0 to -120.0°C (-4 to 248°F) pH Electrode HI 1131B, glass-body, double junction, refillable, BNC connector, 1 m (3.3') cable (included) Temperature Probe HI 7669/2W with 1 m (3.3') cable (included) PC Connection RS232 opto-isolated serial port Data Logging 500 samples Input Impedance 1012 Ohm Power Supply 12 Vdc adapter (included) Environment 0 to 50°C (32 to 122°F); RH max 95% Dimensions 240 x 182 x 74 mm (9.4 x 7.2 x 2.9") Weight 1.1 kg (2.4 lb.) Order Info HI 221 is supplied with HI 1131P refillable pH electrode (glass-body, BNC & Pin with 1m cable), HI 7669/2W stainless steel temperature probe, HI 76404 electrode holder, pH 4 and pH 7 buffer sachets, electrode refilling solution, 12 Vdc power adapter and instructions.
Copyright © 2020 - BC Scientific. All Rights Reserved. Toll-Free: 1.866.597.5960 from 9:30am - 5:00pm EST Email: info@bcscientific.com